Descrizione

The STM32 SMBus driver (drivers/smbus/smbus_stm32.c) implements smbus_block_read() and smbus_block_pcall() by issuing a single i2c_transfer() in which the byte-count byte returned by the peripheral is read directly into the len field of the following i2c_msg. That message then receives data straight into the caller-supplied buffer. Nothing bounds the count, so smbus_stm32_block_read() and smbus_stm32_block_pcall() read up to 255 bytes into a buffer that the SMBus API documents (and the syscall verifiers validate) as holding at most SMBUS_BLOCK_BYTES_MAX (32) bytes. The count is chosen by the addressed SMBus peripheral. A malicious, counterfeit or faulty device on the bus (for example a removable smart battery, PMBus supply or plug-in module), or anyone able to drive the bus lines, can report a block count above 32 and cause the driver to write up to 223 bytes past the end of the caller's buffer. Callers typically pass a 32-byte stack buffer, as the in-tree smbus block_read shell command does, so the overflow lands on the caller's stack before any caller-side count check can run. The result is attacker-controlled stack or memory corruption in the context of the calling thread, which can crash the system or potentially be leveraged for code execution. When the call arrives through the smbus_block_read/smbus_block_pcall system calls, the out-of-bounds write happens in supervisor mode beyond the 32-byte region validated for the user thread. The fix receives the block into a driver-local 255-byte buffer and copies it out only when the count is at most SMBUS_BLOCK_BYTES_MAX, returning -ENODATA otherwise.

Testo originale del record CVE (in inglese).

Come correggere

Priorità: Bassa — correggere con la manutenzione ordinaria. Motivazione: CVSS 6.8, EPSS 0.3% (percentile 13).

Versioni da aggiornare

Il record non riporta ancora i prodotti e le versioni corrette (analisi NVD in corso). Consultare l'advisory del vendor nei riferimenti.

Mitigazioni temporanee

Da applicare solo se non è possibile aggiornare subito:

  • Ridurre la superficie esposta (disattivare servizi e funzionalità inutilizzati), mantenere attive le protezioni del sistema operativo (ASLR, DEP/NX) e segmentare la rete.

Verifica

  1. Individuare tutti gli asset con il prodotto interessato (inventario, scanner di vulnerabilità, CMDB).
  2. Confrontare la versione installata con quelle indicate sopra.
  3. Applicare l'aggiornamento in un ambiente di test, poi in produzione; riavviare i servizi se richiesto.
  4. Ripetere la scansione per confermare la correzione.

Riferimenti